IP65 enclosure
The technical specification lists IP65 protection. Retain the prescribed installation conditions and confirm cable entry and enclosure requirements for the project.

IP65 VECTOR INVERTER
An IP65 wall-mounted inverter with sensorless vector control, built-in PID and Modbus support. Installation conditions follow the supplied V1.11 manual.
Price and availability on request. Final selection is confirmed with your quotation.
English user manual ↗V1.11 · September 2026 · 8.5 MB
IP65 protection does not override the installation requirements. The V1.11 manual specifies indoor installation, no direct sunlight and an ambient temperature of −10 to +40°C. Confirm the proposed environment with sales.
BUILT AROUND YOUR APPLICATION
The technical specification lists IP65 protection. Retain the prescribed installation conditions and confirm cable entry and enclosure requirements for the project.
The manual specifies SVC and V/F operation, with 150% starting torque at 0.5 Hz in SVC mode.
Built-in PID supports pressure and flow regulation. The manual also lists Modbus, multi-speed operation and switching between two motor parameter sets.
TECHNICAL OVERVIEW
Source: V1.11 · September 2026. Match the installed product and manual revision.
| Single-phase 200–240 VAC | 0.4–3.0 kW, S2 models |
|---|---|
| Three-phase 200–240 VAC | 0.4–7.5 kW in Table 2-1 |
| Three-phase 360–440 VAC | 0.75–18.5 kW in Table 2-1 |
| Supply frequency | 50 / 60 Hz |
| Output frequency | 0.00–599.00 Hz |
| Control modes | Open-loop sensorless vector (SVC) and V/F |
| G-type overload | 150% for 60 s; 180% for 3 s |
| Starting torque | 150% at 0.5 Hz in SVC mode |
| Protection class | IP65 |
| Ambient temperature | −10 to +40°C |
| Installation | Indoors, no direct sunlight; below 1,000 m; wall-mounted |
| Communication / process control | Modbus support; built-in PID; up to 16-speed operation |
FIND YOUR MODEL
Use Table 2-1 ratings below for initial selection. Confirm the exact frame drawing, current rating and installation environment before ordering.
Source: PDF page 20 · printed page 14. Codes and ratings follow the manual’s model table. S2 and T2 denote different supply-phase variants; where both appear in one row, confirm the required variant. Full hardware / braking suffixes must be confirmed on the quotation.
| Model reference | Input VAC | Motor kW | Output A | Enquiry |
|---|---|---|---|---|
| ZVF650-G0R4T2/S2 | 200-240 | 0.4 | 2.4 | |
| ZVF650-G0R7T2/S2 | 200-240 | 0.75 | 4.5 | |
| ZVF650-G1R5T2/S2 | 200-240 | 1.5 | 7.0 | |
| ZVF650-G2R2T2/S2 | 200-240 | 2.2 | 10.0 | |
| ZVF650-G3R0T2/S2 | 200-240 | 3.0 | 13.0 | |
| ZVF650-G4R0T2 | 200-240 | 4.0 | 17.0 | |
| ZVF650-G5R5T2 | 200-240 | 5.5 | 20 | |
| ZVF650-G7R5T2 | 200-240 | 7.5 | 30 | |
| ZVF650-G0R7T4 | 360-440 | 0.75 | 2.5 | |
| ZVF650-G1R5T4 | 360-440 | 1.5 | 3.7 | |
| ZVF650-G2R2T4 | 360-440 | 2.2 | 5.0 | |
| ZVF650-G3R0T4 | 360-440 | 3.0 | 6.8 | |
| ZVF650-G4R0T4 | 360-440 | 4.0 | 9.0 | |
| ZVF650-G5R5T4 | 360-440 | 5.5 | 13 | |
| ZVF650-G7R5T4 | 360-440 | 7.5 | 17 | |
| ZVF650-G011T4 | 360-440 | 11 | 25 | |
| ZVF650-G015T4 | 360-440 | 15 | 32 | |
| ZVF650-G018T4 | 360-440 | 18.5 | 37 |
No matching model. Try another code or voltage, or send a general enquiry.
PLAN THE INSTALLATION
Outline drawings and mounting tables are provided in the manual. Use the drawing for the exact ordered frame; do not infer dimensions from motor power alone.
Open dimension drawings ↗Frame assignments in the supplied manual require order-specific confirmation. Request the final outline drawing before preparing mounting holes or a cabinet.