Choose by load duty
G denotes constant-torque duty; P denotes variable-torque duty. Paired power and current values must be read in the same G/P order.

VECTOR INVERTER
A broad power range with separate constant-torque and variable-torque ratings. Explore the supplied legacy specification for your motor and load.
Price and availability on request. Final selection is confirmed with your quotation.
English user manual ↗V3.75 · September 2020 · Legacy reference · 24.3 MB
Legacy document: these specifications follow software V3.75, printed September 2020. Confirm the hardware and software revision before ordering or applying parameters.
BUILT AROUND YOUR APPLICATION
G denotes constant-torque duty; P denotes variable-torque duty. Paired power and current values must be read in the same G/P order.
Use the keypad, external terminals or serial communication. Frequency references include analog signals, keypad settings and RS485.
Built-in PID, multi-speed operation, jogging and acceleration/deceleration settings support application-specific configuration.
TECHNICAL OVERVIEW
Source: V3.75 · September 2020 · Legacy reference. Match the installed product and manual revision.
| Single-phase 200–240 VAC | 0.4–3.7 kW, S2 models |
|---|---|
| Three-phase 200–240 VAC | 0.4–110 kW, T2 models |
| Three-phase 360–440 VAC | 0.75–630 kW; G/P ratings where listed |
| Supply frequency | 50 / 60 Hz |
| Output frequency | 0.00–600.00 Hz |
| Control modes | Sensorless vector (SVC), V/F and torque control |
| G-type overload | 150% for 60 s; 180% for 1 s |
| P-type overload | 120% for 60 s; 150% for 1 s |
| Protection class | IP20 |
| Ambient temperature | −10 to +45°C |
| Installation | Indoors; below 1,000 m; non-condensing |
| Communication / process control | RS485 serial communication; built-in PID |
FIND YOUR MODEL
Select by the motor nameplate current, supply voltage and G/P load duty. Confirm the current product revision and enclosure before ordering.
Source: PDF pages 18–19 · printed pages 13–14. G = constant-torque load; P = variable-torque load. Slash-separated motor kW and output A are in matching G/P order. T2/S2 denotes alternative supply variants. The row with R5R5 is retained exactly as printed and must be confirmed with sales.
| Model reference | Input VAC | Motor kW (G/P) | Output A (G/P) | Enquiry |
|---|---|---|---|---|
| ZVF300H-G0R4T2/S2 | 200-240 | 0.4 | 2.4 | |
| ZVF300H-G0R7T2/S2 | 200-240 | 0.75 | 4.5 | |
| ZVF300H-G1R5T2/S2 | 200-240 | 1.5 | 7.0 | |
| ZVF300H-G2R2T2/S2 | 200-240 | 2.2 | 10.0 | |
| ZVF300H-G3R7T2/S2 | 200-240 | 3.7 | 16.0 | |
| ZVF300H-G5R5T2 | 200-240 | 5.5 | 20 | |
| ZVF300H-G7R5T2 | 200-240 | 7.5 | 30 | |
| ZVF300H-G011T2 | 200-240 | 11 | 42 | |
| ZVF300H-G015T2 | 200-240 | 15 | 55 | |
| ZVF300H-G018T2 | 200-240 | 18.5 | 70 | |
| ZVF300H-G022T2 | 200-240 | 22 | 80 | |
| ZVF300H-G030T2 | 200-240 | 30 | 110 | |
| ZVF300H-G037T2 | 200-240 | 37 | 130 | |
| ZVF300H-G045T2 | 200-240 | 45 | 160 | |
| ZVF300H-G055T2 | 200-240 | 55 | 200 | |
| ZVF300H-G075T2 | 200-240 | 75 | 270 | |
| ZVF300H-G090T2 | 200-240 | 90 | 320 | |
| ZVF300H-G110T2 | 200-240 | 110 | 380 | |
| ZVF300H-G0R7T4 | 360-440 | 0.75 | 2.5 | |
| ZVF300H-G1R5T4 | 360-440 | 1.5 | 3.7 | |
| ZVF300H-G2R2T4 | 360-440 | 2.2 | 5.0 | |
| ZVF300H-G3R7/R5R5T4The legacy manual prints R5R5 in this code. Confirm the order designation with sales. | 360-440 | 3.7/5.5 | 9.0/13 | |
| ZVF300H-G5R5/P7R5T4 | 360-440 | 5.5/7.5 | 13/17 | |
| ZVF300H-G7R5/P011T4 | 360-440 | 7.5/11 | 17/25 | |
| ZVF300H-G011/P015T4 | 360-440 | 11/15 | 25/32 | |
| ZVF300H-G015/P018T4 | 360-440 | 15/18.5 | 32/37 | |
| ZVF300H-G018/P022T4 | 360-440 | 18.5/22 | 37/45 | |
| ZVF300H-G022/P030T4 | 360-440 | 22/30 | 45/60 | |
| ZVF300H-G030/P037T4 | 360-440 | 30/37 | 60/75 | |
| ZVF300H-G037/P045T4 | 360-440 | 37/45 | 75/90 | |
| ZVF300H-G045/P055T4 | 360-440 | 45/55 | 90/110 | |
| ZVF300H-G055/P075T4 | 360-440 | 55/75 | 110/150 | |
| ZVF300H-G075/P090T4 | 360-440 | 75/90 | 150/176 | |
| ZVF300H-G090/P110T4 | 360-440 | 90/110 | 176/210 | |
| ZVF300H-G110/P132T4 | 360-440 | 110/132 | 210/253 | |
| ZVF300H-G132/P160T4 | 360-440 | 132/160 | 253/300 | |
| ZVF300H-G160/P185T4 | 360-440 | 160/185 | 300/340 | |
| ZVF300H-G185/P200T4 | 360-440 | 185/200 | 340/380 | |
| ZVF300H-G200/P220T4 | 360-440 | 200/220 | 380/420 | |
| ZVF300H-G220/P250T4 | 360-440 | 220/250 | 420/470 | |
| ZVF300H-G250/P280T4 | 360-440 | 250/280 | 470/520 | |
| ZVF300H-G280/P315T4 | 360-440 | 280/315 | 520/600 | |
| ZVF300H-G315/P350T4 | 360-440 | 315/350 | 600/640 | |
| ZVF300H-G350/P400T4 | 360-440 | 350/400 | 640/690 | |
| ZVF300H-G400/P450T4 | 360-440 | 400/450 | 690/790 | |
| ZVF300H-G450/P500T4 | 360-440 | 450/500 | 790/860 | |
| ZVF300H-G500/P560T4 | 360-440 | 500/560 | 860/950 | |
| ZVF300H-G560/P630T4 | 360-440 | 560/630 | 950/1100 | |
| ZVF300H-G630T4 | 360-440 | 630 | 1100 |
No matching model. Try another code or voltage, or send a general enquiry.
PLAN THE INSTALLATION
Outline drawings and mounting tables are provided in the manual. Use the drawing for the exact ordered frame; do not infer dimensions from motor power alone.
Open dimension drawings ↗ORIGINAL TECHNICAL DOCUMENTATION
Read the complete installation and safety instructions before use. Ratings and functions shown here are a selection overview, not commissioning instructions.
LET’S TALK MOTOR CONTROL